#vitalstream_caretaker_メディカルテクニカ #VitalStream http://medicalteknika.g.dgdg.jp/linkvar/ ラブテック モバイル スマホ タブレット 12誘導心電図伝送 モバイル クラウド カーディオロジ 心電図伝送で実現 お問い合わせは、ラブテック製品輸入元のメディカルテクニカまで 048-928-0168 冠動脈インターベンション 急性心筋梗塞(DoortoBalloon time 90分以内) 心電図伝送を早く導入してSTEMIをたくさん見る病院 90分を満たさなかった症例は不安定狭心症
メディカルテクニカ リンク集 #VitalStream
#vitalstream_caretaker_メディカルテクニカ http://medicalteknika.g.dgdg.jp/linkvar/
メディカルテクニカ有限会社
!doctype>
2009年12月17日木曜日
感想脈でペーシングの文献
Transcoronary pacing for the treatment of bradycardia during percutaneous coronary intervention (PCI) is not well established, but may be a useful technique in interventional cardiology. We developed a porcine model to examine the feasibility and efficacy of transcoronary pacing during PCI. Methods and Results. Eight pigs under general anesthesia underwent unipolar transcoronary pacing with a standard floppy guidewire in a coronary artery (as the cathode) and a skin patch electrode (as the anode). We examined the effect of skin-patch position (groin vs. anterior or posterior chest wall), the presence of an angioplasty balloon on the guidewire and also which coronary artery was “wired” on the efficacy of pacing as assessed by capture and threshold data. Pacing with the bare guidewire and a maximum output of 10 V was successful in 54% of the animals with a groin patch and the anterior chest-wall patch, but in 100% with a posterior chest-wall patch. The pacing thresholds were 8.3 ± 2.2 V, 7.6 ± 2.8 V and 3.4 ± 2.4 V with the patch in these sites, respectively. With an angioplasty balloon over the guidewire, pacing efficacy increased to 100% (irrespective of the target vessel or patch location) and pacing thresholds were significantly reduced (p < 0.05) to 2.7 ± 1.5 (with a groin patch) and 1.0 ± 0.7 V (with a posterior chest-wall patch). With optimal pacing set-up (posterior chest-wall patch and angioplastyballoon insulation), pacing thresholds were similar to those obtained with standard bipolar transvenous pacing at 1.2 ± 0.8 V. We did not observe any adverse effects of coronary pacing. Skeletal muscle contraction was only generated at high-output levels. Conclusions. This pig model examines the practicalities of transcoronary pacing and shows that this technique can produce 100% capture at thresholds comparable to the transvenous approach. This technique may have a role during PCI, particularly in an emergency situation.
登録:
コメントの投稿 (Atom)
-
#VitalStream #cardiogenic #shock roadmap #vitalstream_caretaker_メディカルテクニカ #Labtech_Holter #wavelet_algorithm #Pedcath8 #Mennen_Medical #Arte...
-
Non-Invasive Assessment of Liver Fibrosis in Hepatitis B Patients Chinmay Bera * , Division of Gastroenterology, University Health Network T...
-
#Labtech_Holter #Pedcath8_Mennen\Medical #wavelet_algorithm #Arteriograph_Tensiomed #vitalStream_caretaker #Labtech_12leadsECG_Stress #生体情報 ...
0 件のコメント:
コメントを投稿